PRODUCT INTRODUCTION
Á¦Ç°¼Ò°³


8ppm Multifunction Calibrator 3010
1006 DC MilliVolt Source
A high accuracy handheld millivolt source primarily used for voltage injection, with 3 from 1µV to 1V and 0.02% accuracy. Applications include thermocouple simulation and calibration of A/D converters and chart recorders.
RM33 & 52 0~50¡É 0~100% / Á¤È®µµ ¡¾2%RH ¡¾0.2¡É
RM ½Ã¸®ÁîÀÇ »ó´ë½Àµµ ¹× ¿Âµµ Æ®·£½º¹ÌÅÍ´Â Æ÷°ýÀûÀÎ Ãâ·Â ½ÅÈ£ ¹üÀ§¿Í ÃøÁ¤ ¹üÀ§¸¦ Á¦°øÇÕ´Ï´Ù. Æ®·£½º¹ÌÅÍÀÇ ÇÏ¿ì¡Àº º®¸é ¼³Ä¡ÇüÀ̹ǷΠHVAC ¹× °Ç¹° °ü¸®¿ëÀ¸·Î ÀûÇÕÇÕ´Ï´Ù.
1007 DC MilliVolt Potentiometer & Calibrator
The 1007 is a handheld calibrator that can be used for potentiometric voltage measurement in addition to its operation as a millivolt source, with 3 ranges from 1µV to 1V and 0.02% accuracy.
WM33 & 52 -20~80¡É 0~100% / Á¤È®µµ ¡¾2%RH ¡¾0.2¡É
WM33 & 52´Â Ãâ·Â ½ÅÈ£°¡ %RH, À̽½Á¡ ¶Ç´Â Àý´ë½Àµµ¿Í ¿ÂµµÀÎ º®¸é ¼³Ä¡Çü À¯´ÖÀÔ´Ï´Ù. WM ½Ã¸®Áî´Â º®¸é ÀåÂøÇü ¼¾¼°¡ ÇÊ¿äÇÑ °÷ÀÌ¸é ¾îµðµç Ź¿ùÇÑ ÃøÁ¤ Á¤È®µµ¿Í ¾ÈÁ¤¼ºÀ» Á¦°øÇÕ´Ï´Ù.
PCMini70 -30~85¡É 0~100% / Á¤È®µµ ¡¾2%RH ¡¾0.2¡É
PCMini70Àº ±³Ã¼¿ë ÇÏÀ̱׷νº¸¶Æ® ¸ðµâ¿¡ ±â¹ÝÇÑ »ó´ë½Àµµ ¹Ì´Ï ¼¾¼ÀÔ´Ï´Ù.
1010 DC Voltage Calibrator
A highly stable and accurate mains/battery powered calibrator for applications requiring a precision voltage source of low internal resistance. It has five ranges up to 10V with a resolution up to 0.01¥ìV.
WM261 -20~80¡É 0~100% / Á¤È®µµ ¡¾2%RH ¡¾0.2¡É
WM261Àº »ó´ë½Àµµ¿Í ¿ÂµµÀÇ °íÁ¤¹Ð ÃøÁ¤À» À§ÇØ °³¹ßµÇ¾ú½À´Ï´Ù. ÀÌ Æ®·£½º¹ÌÅÍ¿¡¼ ´Ù¾çÇÑ Ãâ·ÂÀÌ °¡´ÉÇÕ´Ï´Ù.
1017 Voltage/Current/Resistance Calibrator
A portable multifunction calibrator with voltage, current, and resistance ranges. The 1017 is suitable for calibrating a wide range of instruments including thermocouples, transducers, transmitters, and platinum resistance thermometers.
WM281 -30~70¡É 0~100% / Á¤È®µµ ¡¾2%RH ¡¾0.4¡É
WM281 »ó´ë½Àµµ Æ®·£½º¹ÌÅÍ´Â ±³Ã¼¿ë ÇÏÀ̱׷νº¸¶Æ® ¸ðµâÀ» Æ÷ÇÔÇÕ´Ï´Ù. ÀÌ ±³Ã¼¿ë ¸ðµâ·Î ¼¾¼ Çìµå¸¦ ÇÏÀ̱׷νº¸¶Æ® ¸ðµâ·Î ±³Ã¼Çϱ⸸ ÇÏ¸é Æ®·£½º¹ÌÅͰ¡ Àç±³Á¤µË´Ï´Ù. °á°úÀûÀ¸·Î À¯Áöº¸¼ö ºñ¿ëÀÌ È® ÁÙ¾îµé°í ´Ù¿îŸÀÓÀÌ ÃÖ¼Òȵ˴ϴÙ.
1021 DC Current Source
A precision portable DC current source suitable for calibration and test applications from micro-amp levels up to 100mA. The 1021 is used to calibrate current sensitive transducers and their associated indicating and recording instruments.
WM291 -30~70¡É 0~100% / Á¤È®µµ ¡¾2%RH ¡¾0.4¡É
WM291 »ó´ë½Àµµ Æ®·£½º¹ÌÅÍ´Â ±³Ã¼¿ë ÇÏÀ̱׷νº¸¶Æ® ¸ðµâÀ» Æ÷ÇÔÇÕ´Ï´Ù. ÀÌ ±³Ã¼¿ë ¸ðµâ·Î ¼¾¼ Çìµå¸¦ ÇÏÀ̱׷νº¸¶Æ® ¸ðµâ·Î ±³Ã¼Çϱ⸸ ÇÏ¸é Æ®·£½º¹ÌÅͰ¡ Àç±³Á¤µË´Ï´Ù. °á°úÀûÀ¸·Î À¯Áöº¸¼ö ºñ¿ëÀÌ È® ÁÙ¾îµé°í ´Ù¿îŸÀÓÀÌ ÃÖ¼Òȵ˴ϴÙ.
1024 DC Current Calibrator
A portable benchtop DC current source for calibration and test applications from nanoamp levels to 100mA. Applications include current transducer testing and calibration and linearity tests on digital and electronic current meters
DT269 -20~80¡É 0~100% / Á¤È®µµ ¡¾2%RH ¡¾0.2¡É
DT269 Æ®·£½º¹ÌÅÍ¿¡´Â I7000 ÇÏÀ̱׷νº¸¶Æ® ¸ðµâÀÌ ÀÖ½À´Ï´Ù. ÀÌ¿Í °°Àº ¼Ö·ç¼Ç ´öºÐ¿¡ ¼¾¼¸¦ ÇöÀå¿¡¼ ½Å¼Ó °£´ÜÇÏ°Ô ±³Ã¼ °¡´ÉÇϹǷΠÀ¯Áöº¸¼ö ºñ¿ëÀÌ È® ÁÙ¾îµì´Ï´Ù. ¼¾¼¸¦ ±³Ã¼ÇÑ ÈÄ¿¡ Æ®·£½º¹ÌÅ͸¦ Àç±³Á¤ÇÒ ÇÊ¿ä´Â ¾ø½À´Ï´Ù.
1030 Voltage and Current Source
A simple operation pocket-sized calibrator suitable for voltage and current loop signal simulation as well as thermocouple simulation. A cost-effective and popular instrument used in various applications across industries.