PRODUCT INTRODUCTION

º»Áú¾ÈÀü ¿ÀÀÏ&¾×È­°¡½º ¼öºÐºÐ¼®±â Liquidew I.S.

0.001~1000 ppm / ¿ÀÀÏ & ¾×ü¼öºÐÇÔ·® ¿Â¶óÀθð´ÏÅÍ
¼®À¯È­ÇÐ, ¹ßÀü¼Ò ¹× Á¦¾à»ê¾÷ µî °¡¿¬¼º ¾×ü ¹× ¹«±Ø¼º ¾×üÀÇ ¼öºÐ ÇÔ·®À» ¿Â¶óÀÎÀ¸·Î ºÐ¼®
ATEX, IECEx, cCSAus µîÀÇ º»Áú¾ÈÀü ¹æÆøÀÎÁõÀÌ µÇ¾îÀÖÀ¸¸ç, KCs ¹æÆøÀÎÁõ °¡´É
19" Rack Module¿¡ 4°³ÀÇ ¼¾¼­¸¦ ÀåÂøÇÏ¿© »ç¿ëÇÏ´Â Multi-Channel Unit ÀÇ Çü½Ä
* ÄÚ¸ÞÃ÷ ³ëÁ¡±³Á¤½Ã½ºÅÛÀ» ÀÌ¿ëÇÏ¿© Á¡°Ë/±³Á¤¼­ºñ½º¸¦ Á¦°øÇØ µå¸®°í ÀÖ½À´Ï´Ù.

»ó¼¼¼³¸í

Sensor
Sensor TechnologyMichell Ceramic Moisture Sensor
Sensor VersionEasidew PRO I.S
Measurement Range0.001 to 1000 ppmw
Higher range on request, actual range dependent on solubility of sample fluid
Calibration Range-100 to +20¡ÆCdp
AccuracyDew point: ¡¾1¡ÆC between -60 and +20¡ÆCdp
Moisture content: ¡¾10% of reading
Dew point: ¡¾2¡ÆC between -60.1 and -100¡ÆCdp
Resolution0.1¡ÆC between +20 and -100¡ÆCdp
Temperature MeasurementPt100
Temperature Measurement Range-20 to +70¡ÆC
Temperature Measurement Accuracy¡¾0.3¡ÆC @ 0¡ÆC
Analysis PressureUp to 45 MPa
Operating Temperature-20 to +60¡ÆC
Sample Flow RateMin 0.01 l/min
Max 10 l/min
0.1 to 0.3 l/min recommended
CalibrationTraceable to British (NPL) and American (NIST) National Humidity Standards
Certification
Hazardous Area CertificationATEX certified by EECS for use in hazardous areas to Ex II 1G EEx ia IIC T4 CCSAUS certified IS Class I, Division 1, Groups A,B, C & D, T4 
IECEx: Ex ia IIC T4
FM: IS/I/1/ABCD/T4 Ta=+60¡ÆC � Ex90385; Entity; IP66
GOST Ex
Pattern ApprovalGOST-R, GOST-K
Control Unit
DisplayTwo line 6-digits LED, displaying moisture content / dew point (user toggle) and temperature
Analogue OutputTwo 4-20 mA (max load 500 ¥Ø)
User-configured for parameter, unit and range
Digital OutputRS485 Modbus RTU
Display ModeMoisture content (ppmw)
Dew point (¡ÆC or ¡ÆF)
Temperature (¡ÆC or ¡ÆF)
Display Resolution0.1¡ÆCdp, 0.1¡ÆFdp, 0.001 ppmw, 0.1¡ÆC temp
AlarmsFour alarm relays. Control action and set-point are user-programmable
Two Form C contacts rated 10 A, 240 V AC or 8 A, 24 V DC. Non-inductive load
Two Form A contacts rated 5 A, 240 V AC or 4 A, 24 V DC. Non-inductive load
I.S. BarriersGalvanic isolation type, integrated to Control Unit
Power Supply85 - 265 V AC, 50/60Hz or 10 - 72 V DC 
10 W max power consumption
Enclosure19" sub rack unit
Dimensions 132 x 483 x 256mm (h x w x d) 
100mm minimum clearance depth for cables and vents
Operating EnvironmentIndoor, safe area, 0 to +50¡ÆC, < 90% RH
Premium Sampling System
Enclosure304 stainless steel (EN1.4301) enclosure
Option for complete enclosure in 316 stainless steel (EN1.4401)
All fixtures stainless steel
Galvanised steel internal mounting plate
Open panel version available for indoor installation
Dimensions 800 x 600 x 300mm (h x w x d)
Enclosure MountingStainless steel wall mounting brackets
Enclosure Ingress ProtectionIP66
Enclosure Temperature ControlHeater/thermostat options for fixed set-point +20¡ÆC or adjustable set-point range 0 to control +50¡ÆC
Heater Power Supply110/120 or 220/240/255 V AC, 50/60 Hz.  
Power consumption 100 W max
Operating EnvironmentShaded position, on or off shore, -20 to +40¡ÆC (-40 to +60¡ÆC max transient)
Enclosure cooling option recommended for climate ambient > +50¡ÆC
Sample Cooling OptionRecommended for process fluid temperatures > +40¡ÆC
Plant water supply required ¡Â +30¡ÆC