Sensor | |
Measurement Range | -100 to +20¡ÆCdp |
Accuracy (dew point) | ¡¾1¡ÆC from -60 to +20¡ÆCdp ¡¾2¡ÆC from -100 to -60¡ÆCdp |
Enclosure | Stainless steel |
Ingress Protection | IP66 in accordance with standard BS EN 60529:1992 NEMA 4 in protection and accordance with standard NEMA 250-2003 |
Operating Temperature | -40 to +60¡ÆC compensated over -20 to +40¡ÆC |
Storage Temperature | -40 to +109¡ÆC |
Operating Pressure | From vacuum to 40 MPa (400 barg/5801 psig) (max) |
Flow Rate | 1 to 5 Nl/min |
Gas Velocity | 0 to 10m/sec |
Process Connection | 5/8" UNF parallel thread |
Sensor Calibration | Traceable to UKAS and NIST |
Analyzer | |
Measurement Units | ¡ÆC, ¡ÆF dew point; ppmV with user selectable range and resolution; lb/MMscf range dependent on pressure (natural gas); g/m©ø (natural gas) Digital processing and linearization with active or passive pressure compensation |
Resolution | 0.1 ¡ÆC from -80 to +20¡ÆCdp 1¡ÆC from -100 to -80¡ÆCdp |
Secondary Measurement Variable | Pressure using an optional external transducer over a range of 0-45 MPa (450 barg/6527 psig Completely user-configurable for any industry standard transducer with an 4-20 mA output Automatic compensation for ppmV, lbs/MMscf and g/m©ø units |
Alarm Relays | Two user adjustable isolated 10A form 'C' rated at 240 V AC or 24 V DC |
Outputs: | |
Analog | 4-20 mA as standard (max load 500 ¥Ø) user configurable and scalable |
Digital | RS232 |
Power Supply | Universal 85 to 265 V AC, 50/60 Hz or 95 to 370 V DC |
Operating conditions | |
Operating Temperature | |
Analyzer | 0 to +50¡ÆC |
Sensor | -20 to +50¡ÆC (-5 to +122¡ÆF) |
Ingress Protection | |
Analyzer | IP54 (NEMA 12) standard (front panel only) IP66 (NEMA4) with optional cover (front panel only) |
Sensor | IP66 (NEMA4) |
Options | |
Outputs: | |
Analog | 0-20 mA optional (max load 500 ¥Ø) 0-10 V optional (min load 5 K ¥Ø) both user-configurable and scalable |
Digital | RS485: provides 2-way communication - full data access to user and total instrument configuration |
Alarm Relays | 1 or 2 additional 5 A relays (max 4 total) n/o type fully user configurable and adjustable over the full range, full choice of units and sensor fault alarm functions |
Power Supply | 18 to 36 V AC; 9 to 60 V DC |
Cable | Standard 2m (1200m max) |